Welding Consumables
SAW [Flux & Wire Combination]

  • S-737 × H-14
  • Type : Neutral
  • Industry :
  • AWS : A5.17/ASME SFA5.17 F7A(P)4-EH14
  • JIS : Z3183 S502-H
  • EN : ISO 14174 S A AB 1 / 14171 S4

Applications

Horizontal welding of oil storage tanks, ships, bridges, pressure vessels, penstocks, boilers and structural steels.

Characteristics on Usage

Inactive, neutral type bonded flux which is applicable to all kinds of wire. Impact value of weld metal and crack resistibility are good. Slag detachability in the groove and resistance to porosity are good. Usability in horizontal fillet welding and X-ray performance are good.

Notes on Usage

① Dry the flux at 300~350°C (572~662°F ) for 60 minutes before use.
② Remove rust, scales, oil, paint, water, dirt and slag of tack welds from the groove to obtain sound weld metal.
③ Use welding current and speed as low as possible at the first layer of groove to avoid cracking.
④ Preheat at 50~100°C (122~212°F) according to base metal and plate thickness. Keep interpass temperature at 100~250°C (212~482°F ).